印度LED照明灯具客户需线材和LED球泡灯
印度三哥找线材和这个球泡的Sanjay RaiSr. Purchase Executive
Email: **** Hidden Message *****
Con - +91-**** Hidden Message *****(Whatsapp)
PSM GLOBAL IMPEX – New Delhi 110037
#Item DescriptionsYour replies to the requiredtech. SpecificationsQuantity
1Surface mounteddistribution box 7000 set
a) Wall mounted box for miniaturecircuit breakers
b) Integrated 35mm DIN rail (standardprofile rail)
c) Ingress protection rating minimumIP30
d) Fully isolated
e) Enough space for minimum 2 unitsof miniature circuit breaker, minimum 35 or 36mm in total width
f) 2 pieces integrated or separatelysupplied junction terminals for neutral and earth conductors; g) connection of each up to 6conductors 1.5 and 2.5 mm² solid copper and one conductor 16mm² solidaluminum or copper conductor, h) not more than 2 conductors of samecross section per one screw terminal
i) Suitably prepared entries or knock-outs for standard cable sizes fromall four sides
j) Including all screws
k) Packaging: It is preferred thatthe distribution box including the above specified accessories is packed asan individual set. Alternatively the individual members of the set areallowed to be supplied in bulk but only in quantities of no more than 500 piecesin one box.
2Coverstrip 7000 piece
a) Cover strip for miniature circuitbreaker not installed in the surface mounted distribution box; b) if the distribution box offered isspecified for 2 miniature circuit breakers (MCB), a cover strip is needed for1 MCB; c) if the distribution box canaccommodate 4 MCBs, cover strips for 3 MCBs must be supplied
d) Picture for illustration showscover strip for 12 units, the number of units needed depends on the size ofthe box
e) Easy to separate on site
3Warningsign 7000 piece
a) Minimum height 20mm
b) Self-adhesive
c) Long lasting quality
4Miniaturecircuit breaker, 6A 6500 pieces
a) For DIN rail (standard profilerail) installation
b) Size suitable to be installed inthe surface mounted distribution box, leaving space to install a secondminiature circuit breaker for later extensions
c) Rated current 6A, curve “B”
d) Single pole
e) Incoming conductor cross sectionup to 16mm² aluminum
f) Outgoing conductor cross sectionup to 16mm²
5Miniaturecircuit breaker, 16A 500 pieces
g) For DIN rail (standard profilerail) installation
h) Size suitable to be installed inthe surface mounted distribution box, leaving space to install a secondminiature circuit breaker for later extensions
i) Rated current 16A, curve “B”
j) Single pole
k) Incoming conductor cross sectionup to 16mm² aluminum
l) Outgoing conductor cross sectionup to 16mm²
6Lightswitch, 1G 14000 pieces
a) 1 Gang
b) 250V, 10A, AC
c) Clamping connection capacity 2.5mm²
d) Robust and high quanlity
e) Bright white color
f) According to BS standard
7Lightswitch, 3G 7000 piece
a) 3 Gang
b) 250V, 10A, AC
c) Clamping connection capacity 2.5mm²
d) Robust and high quanlity
e) Bright white color
f) According to BS standard
8Surfacemounted box 21000 pieces
a) For light switches
b) Surface mounted box
c) Fully compatible with light switch
d) Incl. allscrews needed to install the switch
e) Knock-outsfor the cable on minimum top and bottom side
f) Brightwhite color, identical to switch
g) According to BS standard
9Doublesocket 21000 set
a) 2 Gang Double pole switched socketoutlet
b) 13A
c) Including surface mounted box
d) Bright white color
e) Robust and high quality
f) According to BS standard
10LED lamp 22000 piece
a) LED lamp
b) Minimum 6W, maximum 9W
c) Minimum light current 600 lm
d) Light temperature 4000K, neutralwhite
e) Edison E27 screw base
f) Average rated life 20000 hours
g) Switching cycles 15000
h) Non-flickering
i) Instant 100% light
j) Angle of radiation >= 200°
k) Supply full data sheet orcatalogue with high-quality pictures, dimensions and full technicalspecification
11Bulbfitting 21000 pieces
a) For wall and roof mounting
b) Edison E27 screw base
c) Fully suitable for the LED lampsupplied and other standard lamps
d) Supply full data sheet orcatalogue with high-quality pictures, dimensions and full technicalspecification
12Twin andearth cable, 1.5mm² 210000 meter
a) 2x 1.5mm² massive copper conductor
b) 70°C conductor temperature
c) PVC insulation and sheath
d) Voltage rating 300/500V
e) British standard
f) Provide full technical data sheet
g) Packaging - Coils of minimum100m, maximum 500m
13Twin andearth cable, 2.5mm² 175000 meters
a) 2x 2.5mm² massive copper conductor
b) 70°C conductor temperature
c) PVC insulation and sheath
d) Voltage rating 300/500V
e) British standard
f) Provide full technical data sheet
g) Packaging -Coils of minimum 100m,maximum 500m
14Earth rod 500 set
a) Preferably 20mm or 25mm indiameter
b) Copper-plated steel
c) Length 1m … 1.2m
d) Including screw terminal forcopper cable
15Coppercable, 4mm² 2500 meter
a) Single core copper cable
b) 4mm² rigid conductor
c) Yellow-green or black PVC sheath
d) Packaging - In coils of 100 m
16Cable clip 700,000 pieces
a) Cable clip suitable for both twinand earth cable diameters
b) Including hardened steel nail of30 or 35mm length
17Screw 175,000 piece
a) 4x35mm
b) Galvanizedsteel
c) Fully suitablefor wall plug
18Wall plug 1,75,000piece
a) 6mm diameter
b) 30mm length
c) PVC
19 Junctionbox 14,000piece
a) Ingress protection rating IP 54
b) Approximate size 80 x 80 x35 mm³
c) 2 or 3 self-sealing cut cableinlets for cables up to 3 x 2.5mm² on each side
d) Exterior mounting flaps withtransverse and oblong holes ensure subsequent alignment
20Connectorfor junction box 56,000piece
a) Screw or push wire connector forup to 5 massive copper conductors 1.5 or 2.5 mm²
b) For 300V AC
c) Packaging - Supply in bulkallowed, screw connectors, 12 connectors in one bar
21Fireextinguisher 60sets
a) 6 kg dry powder
b) With bracket for wall mounting
c) Specification according BS EN 3
22Smokedetector 120set
a) Optical/photoelectric smokedetection
b) Loud alarm signal, 85 dBA at10 feet
c) Test botton
d) Optical and acoustic signal forlow battery
e) Battery lifetime minimum 2 years
f) Including first set of batteries
g) Including screws for wall mounting
thanks 谢谢分享 thanks so much LET ME SEE, PLEASE 谢谢分享 thanks。。。。 谢谢分享 Thanks....